37
RF MEA
SUREMENT
INPUT
IMPEDANCE
50 Ω
CONNECTION
BNC (
50 Ω)
MAXIMUM
VOLTAGE
3.3 V pk
-
pk
Internally Protected
FREQUENCY
10 kHz
–
10 MHz
INPUT
COMPATIBILIT
Y
CURRENT
TRANSFORMER
Pearson Electron
ics (Typical)
ATTENUAT
ION
RATIOS
0.1:1 (Pea
rson Model 411)
1:1 (Pearson Mod
el 4100)
User Selectable
VOLTAGE
(RMS)
100 mV RANG
E
0.20
–
70.00 mV RMS
0.01 mV
Resolution
1000 mV
RANGE
2.0
–
7
00.0 mV RMS
0.1 mV Re
solution
VOLTAGE
(pk
,
pk
-
pk
)
100 mV RANG
E
0.20
–
100.0 mV
0.01 mV
Resolution
1000 mV
RANGE
2.0
–
1
000.0 mV
0.1 mV Re
solution
ACCURACY,
100 mV RANG
E
f ≤ 1.0 MHz
1.0 MHz <
f
≤
2.5 MHz
f > 2.5 MHz
Input
≤ 10.0 mV
± 1% Reading
Or ± 0.25 mV
± 1% Reading
Or ± 0.25 mV
± 1% Reading
Or ± 1.0 mV
10.0 mV < Input ≤
35.0 mV
± 1% Reading
Or ± 0.25 mV
± (1% Reading
+ 0.5% Range)
± (6% Reading +
0.5% Range)
In
put
> 35.0 mV
± 1% Reading
Or ± 0.25 mV
± (1% Reading
+ 0.5% R
ange)
± (6% Reading +
5% Range)
ACCURACY,
1000 mV
RANGE
ƒ ≤ 2.5 MHz
ƒ > 2.5 MHz
Input ≤ 50 mV
± 1% Reading
Or
± 1 mV
± 1% Reading
Or
± 1 mV
50 mV < Input ≤
400.0 mV
± 1% Reading
± 4% Readi
ng
Input > 400.0 mV
± (1% Reading +
0.25% Range)
± (4% Reading +
0.25% Range)
SPECIFICA
T
IONS
1
2
...
40
41
42
43
44
45
46
47
48
49
50
51
52
ELECTROSURGICAL
1
UNIT ANALYZER
1
TABLE OF CONTENTS
3
BC BIOMEDICAL
3
ESU-2050 SERIES
3
CAUTION - SERVICE
5
CAUTION - ENVIRONMENT
5
CAUTION - CLEANING
5
CAUTION - INSPECTION
5
NOTICE – CE
6
NOTICE – SYMBOLS
7
NOTICE – ABBREVIATIONS
7
NOTICE – DISCLAIMER
8
NOTICE – CONTACT INFORMATION
8
NOTICE – PERFORMING TESTS
8
TYPICAL TEST SETUP
12
OVERVIEW
13
(ESU-2050P Only)
15
Attenuation in
19
Independent
22
POWER UP SETTINGS
31
GRAPH MODE
33
ERROR MESSAGES
36
TECHNOLOGY
37
COMMUNICATION PROTOCOL
38
CONFigure Subsystem
40
MANUAL REVISIONS
44
LIMITED WARRANTY
44
SPECIFICATIONS
45
CALCULATED RANGES
46
Kommentare zu diesen Handbüchern
Keine Kommentare
Publish
Verwandte Produkte und Handbücher für Messen, Testen & Steuern BC Biomedical ESU-2000 Series Guide
Messen, Testen & Steuern BC Biomedical SA-2001 Bedienungsanleitung
(28 Seiten)
Messen, Testen & Steuern BC Biomedical USP-100A Bedienungsanleitung
(20 Seiten)
Messen, Testen & Steuern BC Biomedical DPM-2100 Bedienungsanleitung
(28 Seiten)
Dokument drucken
Seite drucken 45
Kommentare zu diesen Handbüchern